Investigations

Browse the PSI investigations and their extracted conditions.

Hardware families

Hardware families as listed in the NASA Space Apps 2026 'Flame in Freefall' challenge statement: challenge statement.

E-FIELD Flames: partial gravity “was mimicked in ACME's Electric-Field Effects on Laminar Diffusion Flames (E-FIELD Flames) experiment through the effect of the electric field on the ions that naturally occur in flames.” An analog, not partial-gravity data.

24 investigations. Leg tags cite PSI quotations in the lenses data.

SelectInvestigationHardwareTestsO₂ rangePressure rangeFlowGravityRelevance and legs
PSI-10 · ACME/Flame DesignAdvanced Combustion via Microgravity Experiments (ACME), Combustion Integrated Rack (CIR), Reconfiguration of Combustion Integrated Rack (CIR)32719.8% – 40.0%43 kPa (6.24 psia) – 305 kPa (44.2 psia)Not in extracted test rowsmicrogravityindirect prevention
PSI-20 · ACME BRECombustion Integrated Rack (CIR), ACME1821.0% – 40.0%56 kPa (8.12 psia) – 101 kPa (14.7 psia)Not in extracted test rowsmicrogravitydirect prevention
PSI-21 · ACME CLD FlameCombustion Integrated Rack (CIR), ACME6Not in extracted test rowsNot in extracted test rowsNot in extracted test rowsmicrogravityindirect preventionsuppression
PSI-22 · ACME E-FIELD FlamesCombustion Integrated Rack (CIR), ACME20Not in extracted test rowsNot in extracted test rowsNot in extracted test rowsmicrogravityindirect
PSI-23 · ACME s-FlameCombustion Integrated Rack (CIR), ACME1821.0% – 30.0%101 kPa (14.7 psia)Not in extracted test rowsmicrogravityfundamental prevention
PSI-25 · BASS-IIMicrogravity Science Glovebox (MSG)12913.6% – 22.2%101 kPa (14.7 psia)Not in extracted test rowsmicrogravitydirect detectionpreventionsuppression
PSI-26 · BASSMicrogravity Science Glovebox11615.9% – 22.7%98.3 kPa (14.3 psia) – 102 kPa (14.8 psia)Not in extracted test rowsmicrogravitydirect preventionsuppression
PSI-39 · CFIMulti-User Droplet Combustion Apparatus (MDCA), Combustion Integrated Rack (CIR)7917.0% – 21.0%50.7 kPa (7.35 psia) – 507 kPa (73.5 psia)Not in extracted test rowsNot stated in PSIindirect
PSI-47 · DAFT / DAFT-2TSI P-Trak0Not in extracted test rowsNot in extracted test rowsNot in extracted test rowsNot stated in PSIindirect detection
PSI-60 · Computational and Experimental Analysis of SPICE Data SetsNot stated in PSI0Not in extracted test rowsNot in extracted test rowsNot in extracted test rowsNot stated in PSIindirect
PSI-62 · Concurrent Flame Spread Modeling using Flamelet Generated Manifolds in Microgravity with Comparison to BASS Experiments using Two-Color TomographyNot stated in PSI0Not in extracted test rowsNot in extracted test rowsNot in extracted test rowsNot stated in PSIindirect prevention
PSI-68 · FLEX-2Combustion Integrated Rack (CIR), Multi-user Droplet Combustion Appartatus (MDCA)817.0% – 30.0%50.7 kPa (7.35 psia) – 304 kPa (44.1 psia)0.1..5microgravityfundamental prevention
PSI-69 · FLEXCombustion Integrated Rack (CIR)-Fluids and Combustion Facility (FCF), Multi-user Droplet Combustion Appartatus (MDCA)27412.0% – 34.0%70.2 kPa (10.2 psia) – 309 kPa (44.9 psia)Not in extracted test rowsmicrogravitydirect preventionsuppression
PSI-98 · SAFFIRE-ISaffire 1 enclosure in Cygnus20.215, 0.215..0.217Not in extracted test rows20 cm/smicrogravitydirect prevention
PSI-99 · SAFFIRE-IICygnus Pressurized Cargo Module, SAFFIRE90.215, 0.219..0.22, 0.22..0.221, 0.221Not in extracted test rows20 cm/smicrogravitydirect prevention
PSI-100 · SAFFIRE-IIISaffire III enclosure in Cygnus20.21..0.212Not in extracted test rows30 cm/smicrogravitydirect prevention
PSI-101 · SAME-RComparitive Soot Diagnostic Hardware; Refer to final report66Not in extracted test rowsNot in extracted test rows0 cm/s – 8.1 cm/smicrogravitydirect detection
PSI-102 · SAMEComparitive Soot Diagnostic Hardware8Not in extracted test rowsNot in extracted test rowsNot in extracted test rowsmicrogravitydirect detection
PSI-106 · SLICENot stated in PSI11Not in extracted test rowsNot in extracted test rowsNot in extracted test rowsNot stated in PSIindirect
PSI-107 · SPICEMicrogravity Science Glovebox (MSG)151Not in extracted test rowsNot in extracted test rows0.66 cm/s – 85.28 cm/smicrogravityindirect
PSI-115 · Utilization of the Smoke Aerosol Measurement Experiment Data for Advanced Modeling and Simulation of Smoke Generation in Micro-GravityNot stated in PSI0Not in extracted test rowsNot in extracted test rowsNot in extracted test rowsNot stated in PSIfundamental detection
PSI-117 · Effect of External Thermo-Convective Perturbation on Cool Flame Dynamics: A Multidimensional Multi-Physics CFD AnalysisNot stated in PSI0Not in extracted test rowsNot in extracted test rowsNot in extracted test rowsNot stated in PSIindirect
PSI-142 · Quantitative Studies of Cool Flame Transitions at Radiation / Stretch Extinction Using Counterflow FlamesPrincipal Investigator Laboratory Hardware0Not in extracted test rowsNot in extracted test rowsNot in extracted test rowsNot stated in PSIfundamental prevention
PSI-159 · ACME CFI-GACME, Combustion Integrated Rack (CIR)33318.0% – 40.0%49.5 kPa (7.18 psia) – 331 kPa (48 psia)Not in extracted test rowsmicrogravityindirect

Materials and oxygen · Compare investigations · Download data

Help center

Every page, button and number explained. Loading the topics… Press the ? menu, then Help mode, to point at anything.

Pick a topic on the left, or search.